Class DistanceSourceToPatient

  • All Implemented Interfaces:
    org.dcm4che.typeddicom.AttributesWrapper, org.dcm4che.typeddicom.DataElementWrapper, org.dcm4che.typeddicom.valuerepresentations.BytesDataElementWrapper, DecimalStringWrapper, org.dcm4che.typeddicom.valuerepresentations.DoubleDataElementWrapper, org.dcm4che.typeddicom.valuerepresentations.FloatDataElementWrapper, org.dcm4che.typeddicom.valuerepresentations.StringDataElementWrapper

    public class DistanceSourceToPatient
    extends org.dcm4che.typeddicom.AbstractDataElementWrapper
    implements DecimalStringWrapper
    Name: Distance Source to Patient
    Keyword: DistanceSourceToPatient
    Tag: (0018,1111)
    Value Representation: DecimalString
    Value Multiplicity: 1
    • Described in the contexts: as follows:
      Attribute Name: Distance Source to Patient
      Type: 3
      Attribute Description:

      Distance in mm from source to center of field of view.

      Note
      1. This value is traditionally referred to as Source Object Distance (SOD).

      2. For cardiovascular image equipment the SOD value typically is the distance from source to isocenter.


    • Described in the contexts: as follows:
      Attribute Name: Distance Source to Patient
      Type: 3
      Attribute Description:

      Distance in mm from source to the table, support or bucky side that is closest to the Imaging Subject, as measured along the central ray of the X-Ray beam.

      Note
      1. This definition is less useful in terms of estimating geometric magnification than a measurement to a defined point within the Imaging Subject, but accounts for what is realistically measurable in an automated fashion in a clinical setting.

      2. This measurement does not take into account any air gap between the Imaging Subject and the "front" of the table or bucky.

      3. If the detector is not mounted in a table or bucky, then the actual position relative to the patient is implementation or operator defined.

      4. This value is traditionally referred to as Source Object Distance (SOD).

      See DICOM Standard Part 3 - Section C.8.11.7 for explanation if Positioner Type (0018,1508) is MAMMOGRAPHIC.


    • Described in the contexts: as follows:
      Attribute Name: Distance Source to Patient
      Type: 3
      Attribute Description:

      Distance in mm from source to center of field of view.

      Note

      This value is traditionally referred to as Source Object Distance (SOD).


    • Described in the contexts: as follows:
      Attribute Name: Distance Source to Patient
      Type: 3
      Attribute Description:

      Distance in mm from source to isocenter (center of field of view).

      Note

      This value is traditionally referred to as Source Object Distance (SOD).


    • Described in the contexts: as follows:
      Attribute Name: Distance Source to Patient
      Type: 1
      Attribute Description:

      Distance in mm from source to the breast support side that is closest to the Imaging Subject, as measured along the X-Ray beam vector.

      Note
      1. This value is traditionally referred to as Source Object Distance (SOD).

      2. See notes for this Attribute in DICOM Standard Part 3 - Section C.8.11.5 DICOM Standard Part 3 - Section C.8.11.5.

      3. See DICOM Standard Part 3 - Section C.8.11.7.1.1 for description of X-Ray beam vector.


    • Described in the contexts: as follows:
      Attribute Name: Distance Source to Patient
      Type: 3
      Attribute Description:

      Distance in mm from source to the table, support or bucky side that is closest to the Imaging Subject, as measured along the central ray of the X-Ray beam.

      Note
      1. This definition is less useful in terms of estimating geometric magnification than a measurement to a defined point within the Imaging Subject, but accounts for what is realistically measurable in an automated fashion in a clinical setting.

      2. This measurement does not take into account any air gap between the Imaging Subject and the "front" of the table or bucky.

      3. If the detector is not mounted in a table or bucky, then the actual position relative to the patient is implementation or operator defined.

      4. This value is traditionally referred to as Source Object Distance (SOD).


    • Described in the contexts: as follows:
      Attribute Name: Distance Source to Patient
      Type: 3
      Attribute Description:

      Distance in mm from source to the breast support side that is closest to the Imaging Subject, as measured along the X-Ray beam vector.

      Note
      1. This value is traditionally referred to as Source Object Distance (SOD).

      2. See notes for this Attribute in DICOM Standard Part 3 - Section C.8.11.5 DICOM Standard Part 3 - Section C.8.11.5.

      3. See DICOM Standard Part 3 - Section C.8.11.7.1.1 for description of X-Ray beam vector.


    • Constructor Summary

      Constructors 
      Constructor Description
      DistanceSourceToPatient()
      Creates a new Distance Source to Patient object which wraps a new and empty Attributes object.
      DistanceSourceToPatient​(org.dcm4che3.data.Attributes attributes)
      Creates a new Distance Source to Patient object which wraps the provided attributes.
    • Method Summary

      All Methods Instance Methods Concrete Methods 
      Modifier and Type Method Description
      DistanceSourceToPatient copy()
      Returns a new Distance Source to Patient which wraps a copy of the Attributes wrapped in this Distance Source to Patient.
      java.lang.String getPrivateCreator()  
      int getTag()  
      • Methods inherited from class org.dcm4che.typeddicom.AbstractDataElementWrapper

        equals, exists, getValue, hashCode, toString
      • Methods inherited from class org.dcm4che.typeddicom.AbstractAttributesWrapper

        getAttributes
      • Methods inherited from class java.lang.Object

        clone, finalize, getClass, notify, notifyAll, wait, wait, wait
      • Methods inherited from interface org.dcm4che.typeddicom.AttributesWrapper

        copy, getAttributes, getKnownAttributeTags, getUnknownAttributeTags, isEmpty
      • Methods inherited from interface org.dcm4che.typeddicom.valuerepresentations.BytesDataElementWrapper

        getBytes, getSafeBytes, setBytes
      • Methods inherited from interface org.dcm4che.typeddicom.DataElementWrapper

        exists, getValue
      • Methods inherited from interface org.dcm4che.typeddicom.valuerepresentations.DoubleDataElementWrapper

        getDouble, setDouble
      • Methods inherited from interface org.dcm4che.typeddicom.valuerepresentations.FloatDataElementWrapper

        getFloat, setFloat
      • Methods inherited from interface org.dcm4che.typeddicom.valuerepresentations.StringDataElementWrapper

        getString, setString
    • Constructor Detail

      • DistanceSourceToPatient

        public DistanceSourceToPatient​(org.dcm4che3.data.Attributes attributes)
        Creates a new Distance Source to Patient object which wraps the provided attributes.
        Parameters:
        attributes - the Attributes object to be wrapped.
      • DistanceSourceToPatient

        public DistanceSourceToPatient()
        Creates a new Distance Source to Patient object which wraps a new and empty Attributes object.
    • Method Detail

      • copy

        public DistanceSourceToPatient copy()
        Returns a new Distance Source to Patient which wraps a copy of the Attributes wrapped in this Distance Source to Patient. (see Attributes(Attributes)
        Returns:
        a new Distance Source to Patient which wraps a copy of the Attributes wrapped in this Distance Source to Patient.
      • getPrivateCreator

        public java.lang.String getPrivateCreator()
        Specified by:
        getPrivateCreator in interface org.dcm4che.typeddicom.DataElementWrapper
      • getTag

        public int getTag()
        Specified by:
        getTag in interface org.dcm4che.typeddicom.DataElementWrapper