Class RelativeXRayExposure

All Implemented Interfaces:
AttributesWrapper, DataElementWrapper, BytesDataElementWrapper, IntDataElementWrapper, IntegerStringWrapper, StringDataElementWrapper

public class RelativeXRayExposure extends AbstractDataElementWrapper implements IntegerStringWrapper
Name: Relative X-Ray Exposure
Keyword: RelativeXRayExposure
Tag: (0018,1405)
Value Representation: IS
Value Multiplicity: 1
  • Described in the contexts: as follows:
    Attribute Name: Relative X-Ray Exposure
    Type: 3
    Attribute Description:

    Relative X-Ray exposure on the plate. Meaning of values is implementation specific. May be used to adjust the dynamic range of the plate digitizer (scanner).

    Note

    This value is manufacturer-specific. DICOM specifies Standard Attributes in DICOM Standard Part 3 - Table 10-23, which are recommended.


  • Described in the contexts: as follows:
    Attribute Name: Relative X-Ray Exposure
    Type: 1
    Attribute Description:

    Indication of the applied dose, in manufacturer specific units.

    Note
    1. This value is intended to provide a single location where manufacturer specific information can be found for annotation on a display or film, that has meaning to a knowledgeable observer.

    2. This may be a calculated or measured value. Examples are the detector entrance dose (KB), the CR sensitivity value (S), or the logarithmic median (lgM).

    3. This value is manufacturer-specific. DICOM specifies Standard Attributes in DICOM Standard Part 3 - Table 10-23 'Exposure Index Macro', which are recommended.


  • Described in the contexts: as follows:
    Attribute Name: Relative X-Ray Exposure
    Type: 3
    Attribute Description:

    Indication of the applied dose, in manufacturer specific units.

    Note
    1. This value is intended to provide a single location where manufacturer specific information can be found for annotation on a display or film, that has meaning to a knowledgeable observer.

    2. This may be a calculated or measured value. Examples are the detector entrance dose (KB), the CR sensitivity value (S), or the logarithmic median (lgM).

    3. DICOM specifies Standard Attributes in DICOM Standard Part 3 - Table 10-23 'Exposure Index Macro', which are recommended.


  • Field Details

  • Constructor Details

    • RelativeXRayExposure

      public RelativeXRayExposure(org.dcm4che3.data.Attributes attributes)
      Creates a new Relative X-Ray Exposure object which wraps the provided attributes.
      Parameters:
      attributes - The Attributes object to be wrapped.
    • RelativeXRayExposure

      public RelativeXRayExposure()
      Creates a new Relative X-Ray Exposure object which wraps a new and empty Attributes object.
  • Method Details

    • copy

      public RelativeXRayExposure copy()
      Returns a new Relative X-Ray Exposure which wraps a copy of the Attributes wrapped in this Relative X-Ray Exposure. (see Attributes(Attributes)
      Returns:
      a new Relative X-Ray Exposure which wraps a copy of the Attributes wrapped in this Relative X-Ray Exposure.
    • getTag

      public int getTag()
      Specified by:
      getTag in interface DataElementWrapper
      Returns:
      The DICOM Tag of the wrapped DICOM attributes.