Interface PatientEquipmentRelationshipCodeSequence.Holder
- All Superinterfaces:
AttributesWrapper
- All Known Subinterfaces:
RTRadiationCommonModule,RTRadiationRecordCommonModule
- All Known Implementing Classes:
CArmPhotonElectronRadiationIOD,CArmPhotonElectronRadiationRecordIOD,PatientEquipmentRelationshipCodeSequence.SimpleHolder,PatientTreatmentOrientationSequence.Item,RoboticArmRadiationIOD,RoboticArmRadiationRecordIOD,RTDeliveryStartPatientPositionSequence.Item,RTRadiationSalvageRecordIOD,RTTreatmentPreparationPatientPositionSequence.Item,TomotherapeuticRadiationIOD,TomotherapeuticRadiationRecordIOD
- Enclosing class:
- PatientEquipmentRelationshipCodeSequence
A class implementing this interface can hold attributes which contain the DICOM tag "Patient Equipment Relationship Code Sequence" (see
PatientEquipmentRelationshipCodeSequence)-
Nested Class Summary
Nested ClassesModifier and TypeInterfaceDescriptionstatic class -
Method Summary
Modifier and TypeMethodDescriptionbuilder()builder(org.dcm4che3.data.Attributes attributes) default booleanAdds a new Patient Equipment Relationship Code Sequence (seePatientEquipmentRelationshipCodeSequence) with initial capacity 1 (seeensurePatientEquipmentRelationshipCodeSequence(int)) if it does not already exist.ensurePatientEquipmentRelationshipCodeSequence(int initialCapacity) Adds a new Patient Equipment Relationship Code Sequence (seePatientEquipmentRelationshipCodeSequence) if it does not already exist.newPatientEquipmentRelationshipCodeSequence(int initialCapacity) Adds a new Patient Equipment Relationship Code Sequence.default voidRemoves the Patient Equipment Relationship Code Sequence (seePatientEquipmentRelationshipCodeSequencewrap(org.dcm4che3.data.Attributes attributes) Methods inherited from interface org.dcm4che.typeddicom.AttributesWrapper
copy, getAttributes, isEmpty
-
Method Details
-
wrap
static PatientEquipmentRelationshipCodeSequence.Holder wrap(org.dcm4che3.data.Attributes attributes) - Parameters:
attributes- An attributes object containing the Patient Equipment Relationship Code Sequence (seePatientEquipmentRelationshipCodeSequence)- Returns:
- A wrapper object implementing the
PatientEquipmentRelationshipCodeSequence.Holderinterface.
-
builder
- Returns:
- a
PatientEquipmentRelationshipCodeSequence.Holder.Builderto create Patient Equipment Relationship Code Sequence Items with a fluent API.
-
builder
static PatientEquipmentRelationshipCodeSequence.Holder.Builder builder(org.dcm4che3.data.Attributes attributes) - Parameters:
attributes- The Attributes to be wrapped by thePatientEquipmentRelationshipCodeSequence.Holder.Builder.- Returns:
- a
PatientEquipmentRelationshipCodeSequence.Holder.Builderto create Patient Equipment Relationship Code Sequence Items with a fluent API. Instead of creating new Attributes it wraps the provided Attributes.
-
getPatientEquipmentRelationshipCodeSequence
- Returns:
- the Patient Equipment Relationship Code Sequence (see
PatientEquipmentRelationshipCodeSequence)
-
newPatientEquipmentRelationshipCodeSequence
default PatientEquipmentRelationshipCodeSequence newPatientEquipmentRelationshipCodeSequence(int initialCapacity) Adds a new Patient Equipment Relationship Code Sequence. (seePatientEquipmentRelationshipCodeSequence)- Parameters:
initialCapacity- the initial capacity for the new Patient Equipment Relationship Code Sequence
-
ensurePatientEquipmentRelationshipCodeSequence
default PatientEquipmentRelationshipCodeSequence ensurePatientEquipmentRelationshipCodeSequence(int initialCapacity) Adds a new Patient Equipment Relationship Code Sequence (seePatientEquipmentRelationshipCodeSequence) if it does not already exist. (seeAttributes.ensureSequence(int, int)- Parameters:
initialCapacity- The initial capacity (seeArrayList(int)) if a new Patient Equipment Relationship Code Sequence is created.- Returns:
- Either the already existing Patient Equipment Relationship Code Sequence (see
PatientEquipmentRelationshipCodeSequence) or a new one with capacityinitialCapacity.
-
ensurePatientEquipmentRelationshipCodeSequence
Adds a new Patient Equipment Relationship Code Sequence (seePatientEquipmentRelationshipCodeSequence) with initial capacity 1 (seeensurePatientEquipmentRelationshipCodeSequence(int)) if it does not already exist.- Returns:
- Either the already existing Patient Equipment Relationship Code Sequence (see
PatientEquipmentRelationshipCodeSequence) or a new one with capacity 1.
-
containsPatientEquipmentRelationshipCodeSequence
default boolean containsPatientEquipmentRelationshipCodeSequence()- Returns:
- Whether it contains the Patient Equipment Relationship Code Sequence (see
PatientEquipmentRelationshipCodeSequence)
-
removePatientEquipmentRelationshipCodeSequence
default void removePatientEquipmentRelationshipCodeSequence()Removes the Patient Equipment Relationship Code Sequence (seePatientEquipmentRelationshipCodeSequence
-